e-ISSN: 2717-7149
  • Home
  • About
    • About The Journal
    • Instructions for Authors
    • Privacy Policy
    • Reviewer Process
    • Research and Publication Ethics
  • Editorial Board
  • Contact
Current Issue
Ahead Of Print
Archive
Search
Most Popular
Download Articles Read Articles
Retina Arter Tıkanıklıkları ve Tedavisi...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Bilateral Optic Disc Drusen
Vascular Endothelial Growth Factor and Anti VEGF Agents...
Central Retinal Artery Occlusion As the Cause of Unilateral Concentric Narrowing of Visual Field and Presence of Cilioretinal Artery...
Retina Arter Tıkanıklıkları ve Tedavisi...
Morning Glory Syndrome Associated with Retinochoroidal Coloboma...
Santral Retinal Ven Tıkanıklığı Güncel Tedavisi...
Bilateral Optic Disc Drusen
PureSee Kesintisiz Yüksek Kalitede Görüş
Retina-Vitreous 2025 , Vol 34 , Num 3
Turkish Abstract Abstract Free Full Text English Similar Articles Mail to Author
Comparison Of Multifocal Electroretinography Results With Two Different Electrodes In Patients Using Hydroxychloroquine: A Preliminary Study
Mustafa Subaşı1, İnci Güngör2
1Amasya Merzifon Karamustafa Pasha Public Hospital, Türkiye
2Samsun Ondokuz Mayıs University Ophtalmology Department, Türkiye
DOI : 10.37845/ret.vit.2025.34.28 Purpose: To evaluate retinal electrophysiological responses with two different electrodes in patients who have been using HCQ at a dose of least 200 mg/day for more than five years and who are not known to have hydroxychloroquine (HCQ) retinal toxicity and to compare JET electrode data and H-K loop electrode data.

Method: 20 eyes of 20 participants, 10 patients and 10 controls to whom HCQ treatment will be started, who were admitted consecutively to the clinic between October 2020 and March 2021 and who met the inclusion criteria were evaluated prospectively.

Results: When the P1 wave amplitudes of both electrodes in the patient and control groups were compared, it was obtained lower in all waves in the patient group; Statistically significant difference was observed only in Ring 1 (p=0.029) in JET electrode, in ring 2 (p=0.019) and ring 3 (p=0.009) in H-K loop electrode.

Discussion: The reason for the variation of the affected ring with respect to the electrode may be associated with the recorded localization of the electrode. In this respect, internal consistency of the electrodes draws attention. Keywords : hydroxychloroquine, electroretinography, electrodes